SECS/GEM、测试自动化、AI 视觉和智能工厂的市场领导者

Smart FactorySupportFAQ

S9F9 Transaction Timer Out Message

The S9F9 Transaction Timer Out message is closely related to the T3 Reply Timeout parameter.
If you send a Primary message, you receive a Secondary message to confirm receipt of the message.
If you send a Primary message and do not receive a
Secondary (Reply) message for a certain time (T3 Reply Timeout setting time) XCom automatically sends S9F9 messages.

Unlike other Stream 9 series messages, S9F9 messages are not automatically used as an option in the Configuration Tool but are automatically sent.

Notes
If the Secondary message is not received within the time set by the T3 Timeout parameter.
If the S9F9 message does not occur automatically, the RTY parameter is set to 2 or more. There will be.
Please check.
Retransmit the number of times set by RTY and automatically send S9F9 message with T3 Timeout.

14: 12: 04 [SECS-II: Send]
S5 F23 Device ID = 1 WBit = 1 SystemByte = 000046B9
L 12
BOOL 7 [BoolArray]
BIN 7 [BinaryArray] <01 01 01 01 01 01 01>
U1 7 [U1Array] <1 2 3 4 5 6 7>
U2 7 [U2Array] <1 2 3 4 5 6 7>
U4 7 [U4Array] <1 2 3 4 5 6 7>
U8 7 [U8Array] <1 2 3 4 5 6 7>
I1 7 [I1Array] <1 2 3 4 5 6 7>
I2 7 [I2Array] <1 2 3 4 5 6 7>
I4 7 [I4Array] <1 2 3 4 5 6 7>
I8 7 [I8Array] <1 2 3 4 5 6 7>
F4 7 [F4Array] <1.000000000000 2.000000000000 3.000000000000 4.000000000000 5.000000000000 6.000000000000 7.000000000000>
F8 7 [F8Array] <1.000000000000 2.000000000000 3.000000000000 4.000000000000 5.000000000000 6.000000000000 7.000000000000>

14: 12 : 09 [SECS-II: Send]
S9 F9 Device ID = 1 WBit = 0, SystemByte = 000046BB
BIN 10, <00 01 85 17 00 00 00 00 46 B9>

14: 12: 09 [Proc: Alarm] T3 Timeout: S5F23 SystemByte = 000046B9